Uneven cell voltage is one of the most common issues that reduce the overall performance and service life of electric forklift battery packs, which may lead to insufficient runtime, unexpected power drop during heavy load operations, or even trigger the built-in protection system to cut off power completely. The first step of troubleshooting is to carry out a full appearance inspection of the whole battery pack first, to check for any signs of liquid leakage, loose connection terminals, or damaged insulating layers between adjacent cells, as these external abnormal conditions often cause unstable current transmission and lead to inconsistent voltage readings. After confirming no external damage, staff can use a calibrated professional voltage measuring device to record the open circuit voltage of each single cell one by one, sort out cells with voltage difference beyond the normal allowable range, and mark these cells for further inspection. Next, you need to check the working status of the battery management system, confirm that the BMS can collect voltage data of each cell accurately without data delay or collection deviation, as abnormal BMS settings are a common hidden cause of misjudgment of uneven voltage. After excluding BMS errors, you can perform a balanced charging and discharging test on the whole pack under standard working environment temperature, to observe whether the voltage difference can be reduced to the normal range after one or two full cycles. If the voltage difference still remains at a high level after repeated tests, you can judge that there are individual aging cells with inconsistent internal resistance that need targeted replacement or activation treatment. As a professional service provider focusing on new energy industrial power solutions, Jianshu New Energy has summed up a set of standardized non-destructive troubleshooting processes after years of on-site practice, which can effectively solve most uneven cell voltage faults without dismantling the whole pack unnecessarily. For users who use BYD Forklift products, regular monthly voltage consistency check of the battery pack can reduce the probability of related faults by more than 60%, and extend the total cycle life of the battery pack by 30% on average. If you encounter tricky problems that cannot be solved by routine inspection, you can send your detailed fault description to the mailbox 17399989919@163.com to get targeted professional technical guidance. It is worth noting that all troubleshooting operations should be carried out by certified professional technicians with standard protective equipment, never attempt to disassemble the battery pack privately without relevant operation qualifications to avoid unnecessary safety risks.